25 mm Vacuum Insulated Control Valve

Access full document

Details

Contract Title:25 mm Vacuum Insulated Control Valve
Published Date:Feb 12, 2026
Notice Type:Notice (ContractNotice)
Value Banding:High Value
Delivery Point:United Kingdom

Description:

HSE require a 25 mm control valve for an experimental programme. The valve must be suitable for liquid hydrogen service (down to 20 K) and have continuous analogue control between 0 - 100% open. The valve should be controlled electrically and be rated for ATEX Zone 1. Ex ia/ib electronics are not preferred- Ex d, e, m etc. are the preferred protection concepts. The valve should be vacuum insulated and use bayonet connections (male inlet, female outlet AS Scientific bayonets). Process condition...